Electrical Characterization

Probe Station 1 PM5 (With thermal chuck)​

  • Name: Probe Station 1 PM5(With thermal chuck)
  • Tool No.: MNCF 001
  • Make : Cascade PM5, with Keisight Semiconductor Device Analyzer B1500A

Probe Station 1 PM5 (With thermal chuck)

  • Temperature Range from 20ºC – 200ºC
  • This setup has PM5 integrated with ATT Temperature Controller which is coupled with Semiconductor Device Analyzer B1500A
  • Single-box solution for current-voltage (IV), capacitance-voltage (CV), sheet resistance, Van der pauw measurement .
  • Measurement features include single and multi-channel sweep, time sampling, list sweep, quasi-static CV (using the SMUs).
  • Superior IV measurement performance: 0.1 fA / 0.5 microvolts measurement resolution
  • Integrated capacitance module supports CV measurements from 1kHz- 5 MHz

Technical Documents

Status:
Operational

Sample requirement:
No biological, liquid or corrosive sample

Location: MNCF, Electrical  Bay

Training Videos: DC Probe Station Tool (youtube.com)


Additional Notes

Probe Station 2 PM5 (With Pulsed source)

  • Name: Probe Station 2 PM5 ( with pulsed source)
  • Tool No.: MNCF 001
  • Make : Cascade PM5, with Keisight Semiconductor Device Analyzer B1500A

Probe Station 2 PM5 ( with pulsed source)

  • Single-box solution for current-voltage (IV), capacitance-voltage (CV), sheet resistance, Van der pauw measurement .
  • Measurement features include single and multi-channel sweep, time sampling, list sweep, quasi-static CV (using the SMUs).
  • Superior IV measurement performance: 0.1 fA / 0.5 microvolts measurement resolution
  • Integrated capacitance module supports CV measurements from 1kHz- 5 MHz
  • 10 ns pulsed I-V solution is available for characterizing samples.

Technical Documents

Status:
Operational

Sample requirement:
No biological, liquid or corrosive sample

Location: MNCF, Electrical  Bay

Training Videos: DC Probe Station Tool (youtube.com)


Additional Notes

Probe Station 3-LowTemp LN2(77K-400K) IV-CV

  • Name: Probe Station3-LowTemp LN2(77K-400K) IV-CV
  • Tool No.: MNCF 003
  • Make : Lake Shore Cryotronics

The LN2 probe station is capable of making a wide variety of nondestructive, standard electrical device measurements. The compact table-top design is perfect for academic and laboratory research settings. The LN2 provides efficient cryogenic temperature operation and control with a continuous refrigeration system using liquid nitrogen.

The LN2 operates over a temperature range 77K to 400K-this model accommodates full and partial wafers up to 1.2 inch. A wide selection of probes, cables, sample holders, and options makes it possible to meet specific measurement applications.

Probe Station3-LowTemp LN2(77K-400K) IV-CV

– Temperature range – 77-400K
– 4 probes and 1 chuck connection for bottom contact.
– High Vacuum – 4.5E-05 hpa, Chuck size- 1.5 inch
– Probe Tips : 3 µm, 5 µm, 10 µm and 25µm
– Temperature Controller – Model 336
– Cooling Source – Liquid Nitrogen LN2
– Over pressure safety – 3.5kpa (0.5 psi) pressure relief valve

Technical Documents

Status: Operational

Sample requirement:

Thin films allowed no pellets and biological samples

Sample size must be 1 cm x 1 cm

Location: MNCF, Electrical  Bay

Training Videos: DCP-3 training video new.mp4


Additional Notes

Probe Station 4(He) 5k-500k

  • Name: Probe station4(He)5k-500k
  • Tool No.: MNCF 004
  • Make : Lake Shore Cryotronics

The Cryogenic DC Probe Station-4, Model CRX-VF enables cost effective, stable, reliable and convenient low temperature semiconductor testing and even cryogenic wafer-scale testing of devices and circuits. Built-in vibration isolation, smart thermal management and engineered thermal expansion compensation makes this cryogenic probe station system ideally suited for a wide range of applications spanning from nano-electronics (graphene research, molecular electronics, quantum computing, etc.) to space-based electronics.

The Helium probe station operates over a temperature range 10K to 500K. This model accommodates full and partial wafers up to 1.2 inch. A wide selection of probes, cables, sample holders, and options makes it possible to meet specific measurement applications.

Probe station4(He)5k-500k

– Sample temperature range – ±2T field range <10 K base; 10 K to 400 K control range
– ±1 T field range <10 K base; 10 K to 500 K control range
– Sample stage temperature tolerance – ± 2%(As per our reference sensor GaAlAs diode) <10k to 500K
– Cool down time** Room temperature to within 10 K of base 5.5h
– Warm up time Entire system from base to room temperature 4.5 h
-Typical sample stage only base to maximum temperature <15 min
– Control stability <10 K ±50 mK
– 11 K to 500 K ±10 mK

Technical Documents

Status:
Operational

Sample requirement:
Thin films allowed no pellets and biological samples

Sample size must be 1 cm x 1 cm

Location: MNCF, Electrical  Bay

Training Videos: DCP4 helium videos.mp4


Additional Notes

Electromagnetic station electrical characterization – MNCF

  • Name: Electromagnetic station
  • Tool No.: MNCF 006
  • Make : Polytronic
  • Bipolar power supply up to 30A DC current
  • H shaped electromagnet with Magnetic Field Strength: -1.7 T to +1.7 T
  • Facility to measure both planar and normal Magnetic Field

Essential instrument for operation : Probe Station 2 PM5

Status: Operational

Location: MNCF, Electrical  Bay


Additional Notes

Mercury Probe Station

  • Name: Mercury Probe station
  • Tool No.: MNCF 007
  • Make : MDC’s Mercury Probes

MDC’s Mercury Probes are built for measuring samples without the need of creating metallic contacts. They are used for temporary, non-destructive contact to MOS and bare semiconductor samples at room temperature. They are excellent for monitoring wafer doping and resistivity. Mercury probes work well, for example, with Graphene (FLG), GaN, GaAs and GaP material. The probes work in both front-front and front-back contact configurations.

General Features:-

  • Doping Profiles of bulk or epitaxial layers
  • MOS characterization
  • Permittivity of Dielectrics
  • Detection of residual films on conducting substrates
  • Current-Voltage testing of Photovoltaic devices

Essential instrument for operation : Probe Station 1 PM5

Status: Operational

Location: MNCF, Electrical  Bay


Additional Notes

RF Probe Stn-Network Analyzer (10Mhz-67Ghz)​

  • Name: RF Probe Stn-Network Analyzer(10Mhz-67Ghz)
  • Tool No.: MNCF 005
  • Make : Cascade RF probe station Sumitto 9000
  • X-Y stage Travel: 152 mm x 152 mm (6 in. x 6 in.)
  • Bearings : crossroller
  • Resolution : 5 mm (0.2 in.) per turn
  • Rollout stage travel : 10 cm (3.9 in.)
  • Chuck size Size : 152 mm x 152 mm (6 in. x 6 in.)
  • Flatness : 10 mm (0.39 mils) across total surface
  • Material : nickel plated aluminum
  • Isolation : >100 MW
  • Breakdown bias voltage : >500 V

Make: The Keysight E8361A is a general-purpose network analyzer with the following specifications:

  • Frequency range: 10 to 67,000 MHz
  • Maximum dynamic range: 94 dBm
  • Output power: 10 dBm
  • Measurement speed: <26 µsec/point
  • Trace noise: <0.006 dB
  • TRL/LRM calibration
  • Mixer conversion loss, return loss, isolation, and absolute group delay
  • Amplifier gain compression, harmonic, IMD, and pulsed-RF measurements

Technical Documents

Status:
Operational

Sample requirement:
No biological, liquid or corrosive sample

Location: MNCF, Electrical  Bay

Training Videos: RF Probe Station Tool Training (youtube.com)


Additional Notes

VSM-VersaLab

  • Name: VSM-VersaLab
  • Make : Quantum Design
  • Model: VersaLab PPMS
  • Available modes: VSM and Cryo FMR

1. VSM Mode

  • Lock-in measurement technique isolates sample signal from external mechanical and electronic noise for precise measurement of sample moment
  • Linear transport motor enables centering accuracy within ± 0.04 mm
  • A temperature sensor integrated within the coil set provides sample thermometry via exchange gas coupling
  • Standard sample holders included are a low-background quartz paddle and brass half-tube with quartz spacers and polycarbonate capsules

2. FMR Mode

  • Turn-key FMR spectrometer with easy to use software interface
  • Broadband FMR using a coplanar waveguide
  • Calculates the Effective magnetization (Meff), anisotropy (K), gyromagnetic ratio (γ), damping (α), inhomogeneous broadening (ΔH◦)

1. VSM Mode

  • Temperature Range: 50K to 400K​
  • Magnetic field: 3T​
  • Noise floor : <6.0×10-7 emu @300K​
  • Max measurable moment : 40/peak amplitude(mm)​

Drive Parameters

  • Oscillation Amplitude : 0.1 to 5 mm peak, 2 mm (typical)​
  • Oscillation Frequency: 10 to 60 Hz, 40 Hz (typical)​
  • Averaging Time : 0.5 to 750 seconds, 1 second (typical)​

2. FMR Mode

  • Bandwidth: 2-18GHz
  • Temperature Range: 55K to 400K
  • Magnetic field: 3T

Technical Documents

Status:
Operational

Sample requirement:
powder samples <12 mg, Thin films dimention: <4mmX4mm​. No Liquid samples

Location: MNCF, Electrical  Bay

Training Videos: DC Probe Station Tool (youtube.com)


Additional Notes

CFMS-PPMS

  • Name: CFMS-PPMS
  • Make : Cryogenic Limited
  • Model: 5424
  • Available modes: VSM and Resistivity

1. VSM Mode

  • Magnet able to operate in swept or persistent mode
  • Automated gas handling system and calibration procedure
  • Pick-up coils located close to the samples for highest sensitivity
  • Vibrator fitted with moving coil motion detector for amplitude control
  • Rigid and thermally stable carbon fibre sample rod
  • Active vibration compensation of the drive motor

2. Resistivity Mode

  • The Electrical Transport module provides a capability to perform DC resistance measurements in the range from 100 nΩ to 1 GΩ. Cryogenic offers a selection of sample platforms with different numbers of sample connections and suitable for different sample sizes. Probe wiring options include twisted pairs, miniature coaxial cables (for high-frequency measurements) or triaxial lines (for very low current measurements).
  • 1.Resistance & magnetoresistance
  • 2.Current-Voltage (I-V) characteristics
  • 3.Critical current
Maximum Magnetic field Range ± 7 Tesla
System Refrigeration method Completely cryogen-free
Refrigeration technology Cryocooler (GM or PT)
Central field homogeneity H4E: 0.01 % over 30 × Ø10 mm cylinder at field centre for VSM configurations
Sample Space   Ø30 mm or Ø50 mm depending on final configuration chosen
Sample environment Sample in flowing gas or exchange gas
Temperature range (with continuous gas flow in VTI)     1.6 – 400 K
Temperature control: (with Lake Shore series unit) ±5 mK @ 10 K ±10 mK @100 K ±50 mK @ 300 K
Typical sample cool-down time to 1.6 K 60 minutes
Temperature stabilisation time for a typical 5 K temperature step and ±0.1 K stabilisation. Range: 1 – 70 K 70 – 200 K 200 – 400 K Set time: ~1 minute ~10 minutes ~15 minutes
Typical persistent mode decay rate NbTi coils to 9 T: 30-50 ppm/hr Nb3Sn coils to 18 T: 50-100 ppm/hr
Typical Magnet stability in constant current mode 5 ppm/K

1. VSM Mode

  • VSM frequency- 20 Hz typical
  • VSM amplitude- 2 mm
  • Measurement Range- 10¯⁶ to 100 emu
  • Sample size <5 mm
  • RMS Sensitivity from 0 T to 9 T < 10¯⁶ emu

2. Resistivity Mode

  • Noise base 1nV / √Hz
  • Voltage range 10 nV to 100 V
  • Current range 1 nA to 1 A
  • Measurement accuracy: 0.1% across range: 1Ω to 1MΩ

Technical Documents

Status: Operational

Sample requirement:
powder samples <12 mg, Thin films dimention: <4mmX4mm​. No Liquid samples

Location: SF-27, MNCF Annexe

Training Videos:


Additional Notes

Impedance Analyzer 4294A

  • Name: Impedance Analyzer 4294A
  • Tool No.: MNCF 010
  • Make : Agilent
  • DC Vol.: ± 40V
  • AC Frequency: 40Hz- 110MHz
  • AC Amplitude:- 5mV to 1V
  • Measurements – CV(parallel, series), Dissipation Factor, Impedance, Inductance, Quality Factor Etc.

Essential instrument for operation : Probe Station 2 PM5

Status: Operational

Location: MNCF, Electrical  Bay


Additional Notes